| Technical specifications | HW 3600 | HW 1800 |
|---|---|---|
| Weight | 1860 kg | 1680 kg |
| Pump capacity | 3000 l/h | 2100 l/h |
| No. of pumps | 1 | 1 |
| Primary system pressure | At start-up: 2-6 bar. During operation: 2-6 bar | At start-up: 2-6 bar. During operation: 2-6 bar |
| Max. heating effect | 103 kW | 70 kW |
| Type of burner | Singel stage | Singel stage |
| Technical heating efficiency factor | 94% – highest documented in the industry | 94% – highest documented in the industry |
| Fluid temperature | 0-100°C | 0-100°C |
| Fuel consumption | Average fuel consumption of 3.5 l/h when thawing 200 m2. Max. 9.0 l/h at constant burner operation. | Average fuel consumption of 3.5 l/h when thawing 200 m2. Max. 7.0 l/h at constant burner operation. |
| Diesel | Winter diesel, Arctic Class 2 / Biodiesel BFO2G | Winter diesel, Arctic Class 2 / Biodiesel BFO2G |
| Run time (up to) | Up to 90 hours | Up to 90 hours |
| Capacity, fuel tank | 320 liters | 320 liters |
| HTF fluid | HW HTF fluid | HW HTF fluid |
| HTF-tank volum | Approx. 50 litres | Approx. 50 litres |
| Fluid volume, heater hoses | 0.2 l/m | 0.2 l/m |
| Industrial HW hose | Reinforced heater hose Max. temperature 100°C. Max. pressure 30 bar | Reinforced heater hose Max. temperature 100°C. Max. pressure 30 bar |
| El. connection/energy consumption | 230V/2600W | 230V/1000W |
| Total length, heater hoses | 630 m | 630 m |
| Length, individual hoses per circuit | 210 m | 315 m |
| No of hoses | 3 | 2 |
| External fuel connection | Included | Included |
| Service hatches | 4 hatches for easier service access | 4 hatches for easier service access |
| Additional equipment | ||
| • GSM-control monitoring | Receive alerts via SMS in the event of a problem | Receive alerts via SMS in the event of a problem |
| • GPS Track Unit | GPS positioning and operating log (subscription required) | GPS positioning and operating log (subscription required) |
| • Generator, soundproofed | Cummins 4.8 kW, liquid-cooled 2-cylinder engine | Cummins 4.8 kW, liquid-cooled 2-cylinder engine |
| • Automatic start, generator | Generator starts automatically if mains power is interrupted | Generator starts automatically if mains power is interrupted |
| • Extra power outlet | 16A outlet on power supply | 16A outlet on power supply |
| • LED lights on mast | LED floodlight. Practical and robust floodlight. Attaches to the machine. | LED floodlight. Practical and robust floodlight. Attaches to the machine. |